Detailed
1、 Equipment Overview:
Luwohuayu lwhy series PCR nucleic acid detection laboratory wastewater treatment system consists of wastewater collection unit, wastewater regulation unit, wastewater advanced treatment unit, sedimentation and separation unit, physical treatment unit, biological treatment unit, wastewater comprehensive purification unit, etc. Through chemical pretreatment, chemical advanced treatment, disinfection and sterilization, multi-stage filtration precipitation separation and other treatment processes, the organic, inorganic and biological wastewater generated in the laboratory can be comprehensively treated. Cod, BOD, SS, chroma and heavy metal ions in the wastewater can be effectively removed. According to the composition of different experimental wastewater, different treatment technologies and control systems are used to treat the wastewater Reason.
This series of products have the advantages of advanced technology, advanced technology, reasonable process, high degree of automation, no need of special personnel on duty, good treatment effect, standard discharge, convenient operation and management, beautiful appearance and small floor area
2、 Scope of application:
The equipment is widely used in the comprehensive wastewater treatment of laboratories and laboratories in Colleges and universities, scientific research institutes, medical institutions, biopharmaceuticals, CDC, environmental supervision, product quality inspection, quarantine inspection, drug inspection, blood stations, animal husbandry, hospitals, petrochemical, enterprises and other laboratories and laboratories. With stable performance and high quality treatment results, it has been well received by customers.
3、 Type of wastewater:
1. Sources of laboratory wastewater: laboratory drugs, reagents, test solutions, laboratory wastewater collected after the experiment, residual reagents, expired laboratory reagent reagents and other comprehensive wastewater;
2. Laboratory wastewater composition: inorganic, organic, biological wastewater, etc;
1) Inorganic substances: heavy metal ions, pH value of acid and alkali, halogen ions and other non-metallic ions;
a. Heavy metal ions: Mercury, cadmium, total chromium, hexavalent chromium, lead, manganese, silver, nickel, zinc, iron, cobalt, tin, magnesium, zinc, copper, aluminum, arsenic and other metal cations, as well as heavy metal ion groups (Cr2O7) 2 -, (CuCN) -, (aucn) -, ptcl6) 2 -, etc;
b. Non metallic ions: fluoroacid or fluoride, free cyanide or cyanogen compound, complex ion compound, aso32 -, aso43 -, Hg +, Hg2 +, etc;
c. PH value: nitric acid, hydrochloric acid, phosphoric acid, sulfuric acid, hydrogen peroxide, potassium chloride, calcium chloride, etc;
2) Organic substances: organic solvents, detergents, surfactants, benzene, toluene, xylene, aniline, phenol, polychlorinated biphenyls, benzopyrene, phenols, formaldehyde, acetaldehyde, acrylonitrile, acrolein, alkanes, alkenes, hydrogen fluoride, petroleum, Oils and fats, methanol, aniline, polycyclic aromatic hydrocarbons, nitro compounds, nitrosamines, chlorobenzene, nitrobenzene, ethers And mixed hydrocarbon, bingketone, carbohydrate, halogenated hydrocarbon, protein, organophosphorus pesticide, etc;
3) Biology: pathogens, etc;
a. Pathogens: bacteria, viruses, chlamydia, mycoplasma, spirochete, fungi, Brucella, anthrax, etc;
The wastewater treated by the laboratory integrated wastewater treatment system meets the national discharge standard and can be directly discharged into the municipal sewage pipe network
4、 Implementation standards;
It is in line with the first, second and third class standards of national integrated wastewater discharge standard (GB8978-1996).
5、 Equipment features
1. Wide practicability: it can adapt to the wastewater treatment of various laboratories;
2. Patent technology: a number of advanced patent technologies are used to treat and purify the comprehensive wastewater in multiple processes, which fully meets the discharge standard;
3. High degree of automation: central centralized control, friendly man-machine interface, simple operation, fully automatic operation, no need to be on duty;
4. Automatic protection function: water leakage or leakage automatic protection function, high and low voltage automatic protection function, no waste water protection function, liquid level protection function of each treatment unit, overload protection function of electrical equipment, overload protection function of electrical circuit;
5. Long service life: timing automatic cleaning function, the system automatically cleans the parts to be cleaned regularly, and the service life of components is longer;
6. Low operation cost: low system power, low energy consumption; stable operation, few faults and low maintenance cost; long service life of consumables and low cost of consumables; automatic dosing according to proportion, less drug consumption; no special person on duty, no special management fee, etc;
7. Intelligent integration: through the "one-stop" integrated design, it covers a small area, is easy to install and move, and truly realizes the engineering equipment, beautiful appearance, and does not need to dig multiple treatment pools;
8. Good treatment effect: the wastewater treatment capacity is large, the treatment speed is fast, and the treatment effect is good, which conforms to the national discharge standard, and can be directly discharged into the municipal sewage pipe network
6、 Process flow chart:
7、 Quality assurance
Warranty period of 1 year, free maintenance, free replacement of parts not damaged by the buyer;
After the warranty period, free technical support, cost price to provide accessories
8、 Precautions for use
(1) Self priming pump should be cleaned up regularly to prevent blockage.
(2) After the equipment is used for a period of time, the sludge should be discharged, and the valve at the vent should be opened to discharge the sediment to the sludge tank.
(3) When using, the power supply, reagent level and equipment body should be checked for abnormality before use.
(4) Before using the equipment, it is necessary to check whether the electrical appliances of the equipment system are normal until they are completely qualified.
(5) Equipment users must establish a set of regular maintenance system and drug safety management system.
reminder;
Shandong luwo Environmental Engineering Co., Ltd., a professional laboratory wastewater treatment equipment manufacturer, is a high-tech enterprise integrating wastewater treatment technology research and development, equipment manufacturing, engineering installation and commissioning. It has developed and produced PCR nucleic acid testing laboratory wastewater treatment equipment for many years, and luwohuayu lwhy series PCR nucleic acid testing laboratory wastewater treatment equipment has complete qualification
Luwohuayu lwhy series PCR nucleic acid detection laboratory wastewater treatment system consists of wastewater collection unit, wastewater regulation unit, wastewater advanced treatment unit, sedimentation and separation unit, physical treatment unit, biological treatment unit, wastewater comprehensive purification unit, etc. Through chemical pretreatment, chemical advanced treatment, disinfection and sterilization, multi-stage filtration precipitation separation and other treatment processes, the organic, inorganic and biological wastewater generated in the laboratory can be comprehensively treated. Cod, BOD, SS, chroma and heavy metal ions in the wastewater can be effectively removed. According to the composition of different experimental wastewater, different treatment technologies and control systems are used to treat the wastewater Reason.
This series of products have the advantages of advanced technology, advanced technology, reasonable process, high degree of automation, no need of special personnel on duty, good treatment effect, standard discharge, convenient operation and management, beautiful appearance and small floor area
2、 Scope of application:
The equipment is widely used in the comprehensive wastewater treatment of laboratories and laboratories in Colleges and universities, scientific research institutes, medical institutions, biopharmaceuticals, CDC, environmental supervision, product quality inspection, quarantine inspection, drug inspection, blood stations, animal husbandry, hospitals, petrochemical, enterprises and other laboratories and laboratories. With stable performance and high quality treatment results, it has been well received by customers.
3、 Type of wastewater:
1. Sources of laboratory wastewater: laboratory drugs, reagents, test solutions, laboratory wastewater collected after the experiment, residual reagents, expired laboratory reagent reagents and other comprehensive wastewater;
2. Laboratory wastewater composition: inorganic, organic, biological wastewater, etc;
1) Inorganic substances: heavy metal ions, pH value of acid and alkali, halogen ions and other non-metallic ions;
a. Heavy metal ions: Mercury, cadmium, total chromium, hexavalent chromium, lead, manganese, silver, nickel, zinc, iron, cobalt, tin, magnesium, zinc, copper, aluminum, arsenic and other metal cations, as well as heavy metal ion groups (Cr2O7) 2 -, (CuCN) -, (aucn) -, ptcl6) 2 -, etc;
b. Non metallic ions: fluoroacid or fluoride, free cyanide or cyanogen compound, complex ion compound, aso32 -, aso43 -, Hg +, Hg2 +, etc;
c. PH value: nitric acid, hydrochloric acid, phosphoric acid, sulfuric acid, hydrogen peroxide, potassium chloride, calcium chloride, etc;
2) Organic substances: organic solvents, detergents, surfactants, benzene, toluene, xylene, aniline, phenol, polychlorinated biphenyls, benzopyrene, phenols, formaldehyde, acetaldehyde, acrylonitrile, acrolein, alkanes, alkenes, hydrogen fluoride, petroleum, Oils and fats, methanol, aniline, polycyclic aromatic hydrocarbons, nitro compounds, nitrosamines, chlorobenzene, nitrobenzene, ethers And mixed hydrocarbon, bingketone, carbohydrate, halogenated hydrocarbon, protein, organophosphorus pesticide, etc;
3) Biology: pathogens, etc;
a. Pathogens: bacteria, viruses, chlamydia, mycoplasma, spirochete, fungi, Brucella, anthrax, etc;
The wastewater treated by the laboratory integrated wastewater treatment system meets the national discharge standard and can be directly discharged into the municipal sewage pipe network
4、 Implementation standards;
It is in line with the first, second and third class standards of national integrated wastewater discharge standard (GB8978-1996).
5、 Equipment features
1. Wide practicability: it can adapt to the wastewater treatment of various laboratories;
2. Patent technology: a number of advanced patent technologies are used to treat and purify the comprehensive wastewater in multiple processes, which fully meets the discharge standard;
3. High degree of automation: central centralized control, friendly man-machine interface, simple operation, fully automatic operation, no need to be on duty;
4. Automatic protection function: water leakage or leakage automatic protection function, high and low voltage automatic protection function, no waste water protection function, liquid level protection function of each treatment unit, overload protection function of electrical equipment, overload protection function of electrical circuit;
5. Long service life: timing automatic cleaning function, the system automatically cleans the parts to be cleaned regularly, and the service life of components is longer;
6. Low operation cost: low system power, low energy consumption; stable operation, few faults and low maintenance cost; long service life of consumables and low cost of consumables; automatic dosing according to proportion, less drug consumption; no special person on duty, no special management fee, etc;
7. Intelligent integration: through the "one-stop" integrated design, it covers a small area, is easy to install and move, and truly realizes the engineering equipment, beautiful appearance, and does not need to dig multiple treatment pools;
8. Good treatment effect: the wastewater treatment capacity is large, the treatment speed is fast, and the treatment effect is good, which conforms to the national discharge standard, and can be directly discharged into the municipal sewage pipe network
6、 Process flow chart:
7、 Quality assurance
Warranty period of 1 year, free maintenance, free replacement of parts not damaged by the buyer;
After the warranty period, free technical support, cost price to provide accessories
8、 Precautions for use
(1) Self priming pump should be cleaned up regularly to prevent blockage.
(2) After the equipment is used for a period of time, the sludge should be discharged, and the valve at the vent should be opened to discharge the sediment to the sludge tank.
(3) When using, the power supply, reagent level and equipment body should be checked for abnormality before use.
(4) Before using the equipment, it is necessary to check whether the electrical appliances of the equipment system are normal until they are completely qualified.
(5) Equipment users must establish a set of regular maintenance system and drug safety management system.
reminder;
Shandong luwo Environmental Engineering Co., Ltd., a professional laboratory wastewater treatment equipment manufacturer, is a high-tech enterprise integrating wastewater treatment technology research and development, equipment manufacturing, engineering installation and commissioning. It has developed and produced PCR nucleic acid testing laboratory wastewater treatment equipment for many years, and luwohuayu lwhy series PCR nucleic acid testing laboratory wastewater treatment equipment has complete qualification